en'>

How To Install 3 Pin Plug

How To Install 3 Pin Plug – We know that electricity is our best friend, but also our worst enemy, because if you give yourself a chance to kill yourself, remember to never let yourself down. Now you know everything about security and protection

We also know that all electrical equipment is well grounded and grounded. The reason behind this logic is that on both sides the wire touches the body of metal from the device, or in the case of a small circuit, or a leak inside the device, and someone touches the body of the generating metal, it flows into the body through the human body. the earth, that is, shocked by electricity.

How To Install 3 Pin Plug

This is why a proper system is necessary to protect you and those who touch your metal body. The machine must not be exposed to electric shock.

Amazon.com: Zonelistore 3 Pin Way Waterproof Electrical Wire Connector Plug Automotive Wire Connectors Plug With Wire Awg Marine Pack Of 10

The ground pin must be the first and last to be connected to the disconnecting power supply. For this reason the ground pin is longer than the direct and neutral pin in a 3-pin plug. Here is the reason.

In this way, the excavation is well maintained in the work of safety and protection. Now we know that this is why the ground pin is longer compared to the line and the neutral pin on the three-pin plug.

The first reason is to prevent incorrect operation of the 3-pole plug and the electric motor connected for safety reasons. On the other hand, the 3 pin plug will not connect to the reverse socket because of the thicker ground pin, so it will fit and fit into other bases made into the Neutral or Live Pin socket.

Generally, the basic contact is larger and cannot be inserted directly into the socket or the neutral socket, even by mistake.

Difference Between 2 & 3 Pole

It clearly shows that the resistance is inversely proportional to the area of ​​the conductor. eg. In this case, when the wet body (remember that the wet body has the least resistance) in contact with the metal body of the machine, current leaks. Current will flow through it so that it looks like the easiest path (least resistance) to complete the path. Therefore, there is still an electrical accident in the previous cases.

Third, modern 3-projector wall outlets have safety devices (as shown in the image below) on the line and nerves to prevent anyone (especially children) from inserting objects into it that could cause an electric shock. . In this case, the longer ground pins help open the door for the middle wire and pin, i.e. without longer pins, wire and neutral locking devices for better safety.

Now we know another reason why the ground pin of the 3-pin plug is larger than the neutral and direct pin.

All about electrical and electronic engineering and technology. Follow eCommerce on Facebook, Twitter, Instagram, Pinterest, YouTube and Linkedin to get the latest news or subscribe to the latest tech articles in your inbox.

Wiring Plug Hi Res Stock Photography And Images

Our website is available by showing our online maps to our visitors. Please consider helping us disable your blocker. We rely on advertising revenue to continuously create quality content for you to learn and enjoy for free. The British plug, also known as the British plug, type G plug or BS1363 standard plug according to IEC = International Electrotechnical Commission) is a three-pole plug used for power tools and electrical equipment. There are several types of three plug, such as Type A, B, C, D, E, F, G, H, I, J, K, L, etc. common in UK, Singapore, Hong Kong, Malta, Malaysia, Ireland, Cyprus, Oman, Kuwait, KSA, United Arab Emirates, Israel and other countries with fully or partially compliant IEC regulations.

There are three terminals and one brown (different values ​​depending on the requirement of the load circuit) inside the following UK three pin plug:

The live terminal must be connected to the brown wire (wire). It will carry voltage (and current) from the source to the storage point. Live terminals are also known as Hot, Line or Phase terminals. The live screw pin is electrically connected and connected to the safety fuse input, while the output fuse is connected directly to the pin.

The neutral terminal must be connected to the blue wire. The middle wire provides a path for the current when it is broken around.

Electrical Plug Identification

The ground pins are longer and thicker for safety reasons. Therefore, the green wire must be connected to the yellow pin at the ground terminal.

A standard fuse is produced in the BS1363 plug. The price of a ceramic fuse in the UK can vary depending on the current capacity and the type of load being maintained. The main function of a fuse in UK bases is to protect the power cord, equipment and connected rods and wires in the event of overheating and excessive current.

For example, a 13 A fuse with a family supply voltage of 230 V, 50 Hz is equivalent to approximately 3000 watts (3 kW). If the load current exceeds the speed limit of the fuse (in the event of a fault, e.g. short circuit), it will blow or block the RCD/MCB circuit breaker in the main consumer unit.

Good to know: fuses in three-pole plugs must be rated to BS1363. For example, if a low-power device (1100 W or 700 W) is used to replace a previous high-power device (2.5-3 kW with a 13 amp fuse in the plug), the number of fuses must be reduced according to the current. storage capacity, for example 3A for 700W and 5A for 1100W devices.

Ac Set Black Eu Angle Plug Cable Eu Electrical Cords Standard Vde Extension 3 Prong Power Cord

Cables are used in the hands to prevent cable filtering during normal operation and to pull the wire from the screw terminals. Cable holders or pressure reliefs must be placed firmly around the cable with connecting wires with suitable clips.

Good to know: BS-1363 plug also known as UK plug is the safest plug in the world for these reasons.

We have used the following IEC wire color code for a single 230V supply voltage, applied in the UK and EU. The old UK wiring color codes (before April 2004) are listed below.

All about electrical and electronic engineering and technology. Follow eCommerce on Facebook, Twitter, Instagram, Pinterest, YouTube and Linkedin to get the latest news or subscribe to the latest tech articles in your inbox.

How To Wire A Uk 3 Pin Socket Outlet? Wiring A Bs1363 Socket

Our website is available by showing our online maps to our visitors. Please consider helping us disable your blocker. We rely on advertising revenue to continuously create quality content for you to learn and enjoy for free. The British plug, also known as the British plug, type G plug or BS1363 standard plug according to IEC = International Electrotechnical Commission) is a three-pole plug used for power tools and electrical equipment. There are several types of three plug, such as Type A, B, C, D, E, F, G, H, I, J, K, L, etc. common in UK, Singapore, Hong Kong, Malta, Malaysia, Ireland, Cyprus, Oman, Kuwait, KSA, United Arab Emirates, Israel and other countries with fully or partially compliant IEC regulations.

There are three terminals and one brown (different values ​​depending on the requirement of the load environment) inside the following UK three pin plug:

The live terminal must be connected to the brown wire (wire). It will carry voltage (and current) from the source to the storage point. Live terminals are also known as Hot, Line or Phase terminals. The live screw pin is electrically connected and connected to the safety fuse input, while the output fuse is connected directly to the pin.

The neutral terminal must be connected to the blue wire. The middle wire provides a path for the current when it is broken around.

Buy Cleyean Dryer Adapter 4 Prong To 3 Prong Dryer Plug Adapter Cord Nema 10 30p To 14 30r, 30amp, 250v, Stw 10 Awg, External Green Ground Wire Online At Lowest Price In Turkey. B087nq3y2n

The ground pins are longer and thicker for safety reasons. Therefore, the green wire must be connected to the yellow pin at the ground terminal.

There is a standard fuse that comes in the BS1363 plug (usually 13A). The rating of ceramic fuses in the UK can vary depending on the current capacity and the type of load being maintained. The main function of a UK mains fuse is to protect the cables, equipment and connected rods and wires in the event of overheating and overcurrent.

For example, a 13 A fuse with a family supply voltage of 230 V, 50 Hz is equivalent to approximately 3000 watts (3 kW). If the load current exceeds the speed limit of the fuse (in the event of a fault, e.g. short circuit), it will blow or block the RCD / MCB circuit breaker in the main consumer unit.

Good to know: fuses in three-pole plugs must be rated to BS1363. For example, if a low power device (100 W or 700 W) is used to replace the previous high power device (2.5-3 kW)

How To Wire A Uk 3 Pin Switch Socket? Wiring A Bs1363 Socket

How to install plug in track lighting, how to install spark plug wires, how to wire 3 pin plug, how to install spark plug, how to install 7 pin trailer plug, how to install electric plug, how to install plug in, how to install hinge pin door stop, how to install dryer plug, how to install 4 pin trailer plug, how to install 30 amp rv plug, install 7 pin trailer plug

Leave a Comment